Password MEMO
CARDs offer a protection attribute which controls read- and/or write-access to
the MEMO CARD. If the attribute is set, a user password has to be typed before
the secured function is available. A "master" password allows authorized persons
to read the "user" password and to change this. |
|
| The read- write protection is
valid for the entire memory range. If one of the attributes is activated, the
actual user password has to be prompted, otherwise the command is answered by
an error command. |
| COMMAND
DESCRIPTION | HEX code |
| Change user pass-word
(Rel. 3.00 up) | 66h
|
| Set protection-attribute
(Rel. 3.00 up) | 67h |
| Read protection-attribute (Rel.
3.00 up) | 69h |
| Change master pass-word (Rel. 3.00 up) |
6ah |
| Read
user pass-word (Rel. 3.00 up) |
6bh |
| Reset protection attribute
without storing it | 6ch |
| Set Protection Attribute
MEMO CARDs from release 3.0 and up has the feature of read-
and write-protection. This command sets an attribute which controls read and write
access to the inserted MEMO CARD. The factory preselection is "no protection"-"N".
The read- write protection is valid for the entire memory range.
If one of the attributes is activated, the actual user pass word has to be prompted,
otherwise the command is answered by an error command. |
|
COMMAND-telegram | HEX
code |
|
COMMAND 67h | 66h
|
| Set protection-attribute |
(1Fh 67h 09h DATA1-8 DATA9 CS 04h) |
|
DATA1 - 8 | user pass
word |
| DATA9 |
attribute |
| |
|
ATTRIBUTE | HEX
code |
|
A | all protected
(read and write) |
| R |
read protected |
|
W | write protected |
| N |
no protection (preselected) |
| |
| |
|